I. Preparation stage
1, whether the air compressor station room meets the requirements, whether the space is enough, no shelter around, strictly prohibit the storage of flammable and explosive substances.
2, check the air compressor alarm device control device; fixed screws are fixed, switch is intact, cold dryer, filters, piping, etc. to check whether it is intact, there is no leakage, in addition to checking whether the gas storage tank pressure vessel installation is correct, whether the safety valve is intact, whether the test mark is clear.
Second, the operation stage
1、Start: After connecting the power supply, check whether the panel display is normal, the motor is prohibited from reversing, if there is any display abnormality, you need to immediately disconnect the power supply, check for faults and then reboot!
2、Start: After the air compressor is set to start normally, it is necessary to carefully observe whether various parameters are normal, such as pressure, exhaust temperature, voltage, current, etc. It is also necessary to observe whether the air compressor has any strange thoughts and whether the oil level is normal, etc.