sullair air compressor
Welcome to the official website of Zhengzhou Xinluosi Energy Saving Equipment Co., Ltd
TEL:+8613903813022
Noise reduction technology for screw air compressors
Source: | Author:管理员 | Published time: 2024-03-21 | 384 Views | Share:

1、The main source of noise for screw air compressors is the intake and exhaust ports, and suitable intake and exhaust mufflers should be selected in these areas. The frequency spectrum of the intake noise of the air compressor shows low-frequency characteristics, and the intake muffler should choose a resistance structure or an impedance composite structure mainly based on resistance. The exhaust pressure of the air compressor is high, and the airflow speed is high. A small hole muffler should be used at the exhaust port of the air compressor.

2、 Set up a sound-absorbing tunnel for screw air compressors. The underground or semi underground tunnels of the screw air compressor sound-absorbing tunnel are built with sound-absorbing bricks on the walls of the tunnels. Connect the intake pipe of the air compressor to the sound-absorbing tunnel, allowing air to enter the air compressor through the sound-absorbing tunnel. The use of sound-absorbing tunnels can greatly reduce the intake noise of the air compressor and prolong its service life compared to ordinary silencers.