sullair air compressor
Welcome to the official website of Zhengzhou Xinluosi Energy Saving Equipment Co., Ltd
TEL:+8613903813022
Screw air compressor failure
Source: | Author:管理员 | Published time: 2024-01-11 | 136 Views | Share:

Why does the unit consume a lot of oil or why does the compressed air contain a lot of oil?

The reason for this failure is due to too much cooling dose, the correct position should be observed when the air compressor unit is loaded, at which time the oil level should be no higher than half, and the clogging of the oil return pipe can also cause screw air compressor failure.

The installation of the oil return pipe does not meet the requirements will cause the screw air compressor to consume too much oil;

Exhaust pressure is too low when the unit is running;

Rupture of the oil separating core will cause screw air compressor failure;

Damage to the internal partition of the separating cylinder;

deterioration or over-use of coolant.